A COMPARATIVE ENTHALPY APPROACH FOR CO- AND COUNTERCURRENT FLOW IN CONCENTRIC TUBE HEAT EXCHANGER

  • : Ms Word, Ms Word Format
  • : 70 Pages
  • : ₦3,000 | $25 | ₵60 | Ksh 2720
  • : 1-5 Chapters
  •  
  • Click to DOWNLOAD Materials
A COMPARATIVE ENTHALPY APPROACH FOR CO- AND COUNTERCURRENT FLOW IN CONCENTRIC TUBE HEAT EXCHANGER

ABSTRACT

The comparison Evaluation of a heat transfer coefficient between the countercurrent and cocurrent flow arrangement was carried out on heat trainer, fabricated in Nigeria. The experiments carried out are of two different arrangement; countercurrent flow arrangement and co-current flow arrangement of which countercurrent flow firstly consist of countercurrent flow with cold phase variation, hot phase constancy. Countercurrent flow with hot phase variation and cold phase constancy. Secondly the arrangement is co-current flow arrangement which also consist of two different conditions, which are co-current flow with cold phase variation and hot phase constancy; co-current flow with hot phase variation and cold phase constancy. The equipment involves also liking reading of temperature at different flow rate, having completed the experiment and getting result a critical analysis and evaluation was carried out to get the best arrangement of the experiment. Using the graph plotted i.e. a graph of heat transfer rate per unit area against the log mean temperature difference, A result showing the heat transfer coefficient was observed, This helped to get a conclusion of recommended flow arrangement.

Title Page———i

Certification——–ii

Dedication———iii

Acknowledgement——-iv

Abstract ———vi

Table of Content——–vii

 

Chapter One

1.0 Introduction ——-1

1.1 Statement of Problem——4

1.2 Purpose of the Study——5

1.3 Significance of Study——8

1.4 Limitation——–9

1.5 Scope of Study——-11

 

Chapter Two

2.0 Review of Related Literature —-12

2.6 Summary of Literature Review—- 19

 

Chapter Three

3.0 Research Methodology and Procedure—22

3.1 Population ——–22

3.2 Sample and Sampling Technique—-22

3.3 Validation of the Instrument —-23

3.4 Reliability of the Instrument —–23

3.5 Data Analysis——-23

 

Chapter Four

4.0 Presentation and Discussion of Result—24

4.1 Analysis and interpretaion of Data—25

4.2 Discussion of Results——38

 

Chapter Five

5.0. Summary, Conclusion, and Recommendation  –40

5.1 Summary——–40

5.2 Conclusion——–41

5.3 Recommendation——42

References ———45

Appendix 1——–47

Appendix ———50

A COMPARATIVE ENTHALPY APPROACH FOR CO- AND COUNTERCURRENT FLOW IN CONCENTRIC TUBE HEAT EXCHANGER

 

Sharing is caring!